F20 Fault Code

Veröffentlicht am: 15 Juli 2016
auf dem Kanal: HTP Comfort Solutions LLC.
71,850
50

HTP: Fault Code F20: CONDENSATE FULL: The condensate trap is full. The red light will display and the word LOCKOUT will flash. This code indicates a serious safety issue. The boiler will not restart until the cause is determined by a technician and he pushes the RESET button on the display. During this lockout fault, the pump will be off as indicated on the second line of the display

1. Check condensate lines for obstructions.
2. Check float switch in condensate reservoir.
3. Check wiring from condensate reservoir to 926 control and repair as necessary.

"Cold Funk"
Kevin MacLeod (incompetech.com)
Licensed under Creative Commons: By Attribution 3.0
http://creativecommons.org/licenses/b...


Auf dieser Seite können Sie das Online-Video F20 Fault Code mit der Dauer stunde minuten sekunde in guter Qualität ansehen, das der Benutzer HTP Comfort Solutions LLC. 15 Juli 2016 hochgeladen hat, den Link mit Freunden und Bekannten teilen, dieses Video wurde auf Youtube bereits 71,850 Mal angesehen und es wurde von 50 den Zuschauern gefallen. Viel Spaß beim Betrachtenden Zuschauern gefallen!